10000 Gauss Strong Water Softener Magnetizer For Cooling Water System
Working principle
On use of potential energy which generates from neodymium iron boron permanent magnetic material, and optimal design, forming a crest vertical center field. When water or fluid flow through the vertical magnetic field, will produce an electromotive force, The lattice refinement, The original water fouling crystal particle size from about 3.39 microns to about 0.22 microns, flow rate will be faster, The electromotive force generated greater, The effect is more ideal, To achieve the anti-scaling, scale removal purpose.
Meanwhile, water treated by magnetic field, the electrical conductivity and osmotic pressure changed and microbial cell ruptured, cells stop breeding,which achieve effect of sterilization, and algae removal.
Since the water treated by magnetic field, it will produce tiny electron flow,which change Fe2O3 · nH2O into stable Fe3O4 and generates black magnetic iron oxide which deposited onto the tube wall surface to form a film barrier layer, the oxygen in the water separated from the pipe wall, in this case ,it realize the purpose of removal and prevention of rust .
COMPARATIVE CHART
S.No | MAGNETIC WATER SOFTNER | CHEMICAL BASED SOFTENER |
1. | No Salt required - Time & Cost saving | Salt to be added often |
2. | Is attached as a part of the pipeline | Requires extra plumbing & Space |
3. | Works without operator | Need operator every time |
4. | Good for human consumption | Presence of Sodium sited, so not good for consumption |
5. | Zero maintenance units | Regular maintenance & Services required. |
6. | Magnets have a life of about 20-25 years. | Resin needs replacement years after 3 years |
7. | Continuous flow without choking | Frequently choking |
8. | Useful for generators in scale removal | Does not remove existing scale |
9. | Generate zero pollution | Water pollution is caused due to out flow of the salt. |
10. | Removes existing scales (Calcium & Magnesium). | Does not remove existing Scales |
11. | Output of product remain constant | Out put varies due to operational factors |
12. | Also helps in removing parts of Sulphur | Does not remove sulphur & Iron and Iron |
AAA:
01.What is the capacity(m3/hour)you required for this equipment?
or you could confirm diameter of the water pipe.
02.What is the material for this descaling equipment?
Ordinary carbon steel is Okay? stainless steel(SS304/SS316)?
Which means,what is the source of raw water to be treated?
03.What is the magnet power for it?
ordinary 5000 gauss?higher 10000 gauss or 15000 gauss?
Technical parameters:
model | inlet and outlet | dimension(mm) | flow rate | Vertical center | Working medium | weight | |
mm | inch | diameter*length | m 3 /h | strong magnetism (mt) | temperature ( . C) | Kg | |
YLC-1 | 25 | 1 | 108×330 | 4.9 | 160 | 0-80 | 3 |
YLC-1.5 | 40 | 1.5 | 108×330 | 12 | 160 | 0-80 | 3.5 |
YLC-2 | 50 | 2 | 159×450 | 19 | 160 | 0-80 | 5 |
YLC-2.5 | 65 | 2.5 | 159×450 | 28 | 160 | 0-80 | 11 |
YLC-3 | 80 | 3 | 159×450 | 50 | 160 | 0-80 | 15 |
YLC-4 | 100 | 4 | 219×560 | 80 | 160 | 0-80 | 18 |
YLC-5 | 125 | 5 | 219×600 | 125 | 160 | 0-80 | 21 |
YLC-6 | 150 | 6 | 273×740 | 180 | 160 | 0-80 | 30 |
YLC-8 | 200 | 8 | 325×790 | 320 | 160 | 0-80 | 40 |
YLC-10 | 250 | 10 | 377×850 | 480 | 160 | 0-80 | 50 |
YLC-12 | 300 | 12 | 426×800 | 600 | 160 | 0-80 | 58 |
YLC-14 | 350 | 14 | 478×950 | 750 | 160 | 0-80 | 70 |
YLC-16 | 400 | 16 | 530×1000 | 850 | 160 | 0-80 | 95 |
YLC-18 | 450 | 18 | 630×1050 | 950 | 160 | 0-80 | 116 |
YLC-20 | 500 | 20 | 720×1100 | 1100 | 160 | 0-80 | 148 |